Librairie technique Megger

Librairie technique Megger

La librairie technique de Megger donne accès à une diversité de ressources telles que des guides techniques, des guides d'applications et bien d'autres. En créant un compte Megger, vous pouvez enregistrer vos produits, accéder à de nombreux documents et à des mises à niveau de logiciels pour vos produits.

 

Pour accéder à notre gamme de documents et de ressources techniques, cliquez sur les liens ci-dessous.

Filtrer par type d'application :
    Affichage d'item(s) 11 - 20 de 220 au total
Testing frequency relays with SVERKER900 considering the IEC 60255-181 standard
This application note is more than a description of how to use SVERKER 900 for testing frequency relays. It also wantsto spread the knowledge about IEC standardization in relay protection. Many engineers often associate theIEC series of protection standards IEC 60255-1xx1to relay type testing, and believe that they do not need to have competence about this series of standards. This is a misunderstanding: many of the concepts, definitions and test procedures described in thestandards are there to be used in relay technique, no matter if the role is relay manufacturer, user, or commissioning / maintenance testing engineer ([2], [3]).
Publié : 30 juillet 2020
Télécharger en PDF
DLRO2: long test lead test mode
When measuring very low resistance the four-wire test method has for many years been the standard method. The main advantage being that it simply and easily removes the resistance of the test leads from the measurement. However, what happens when those test leads need to be verylong?
Publié : 27 juillet 2020
Télécharger en PDF
DLRO2: nouveau calculateur de différences
Le premier ohmmètre basse résistance à intégrer un calculateur de différences, permettant de transcrire les changements de résistance en marqueur mobile et en pourcentage. Lorsque plusieurs connexions similaires sont testées, le DLRO2 permet de détecter facilement les petites augmentations de résistance qui finiront par provoquer des défaillances majeures.
Publié : 27 juillet 2020
Télécharger en PDF
DLRO2 safety warnings
Safety warnings for DLRO2
Publié : 14 juillet 2020
Télécharger en PDF
Total Demand Distortion (TDD)
Total Harmonic Distortion (THD) is a common method used to measure the level of waveform distortion.Total Harmonic Distortion (THD) measurements are an effective method of evaluating voltage distortion. However THD can be misleading when evaluating current distortion. THD is the summation of the harmonics presented as a percentage of the fundamental. For voltage THD this will be the summation of the voltage harmonics compared to the fundamental voltage. In a non-faulted condition voltage will always be present so a proper reference always exists.
Publié : 29 avril 2020
Télécharger en PDF
Testing ROCOF protection
Detailed guidance on ROCOF testing with the Sverker 900, including information about connections and instrument settings.
Publié : 29 avril 2020
Télécharger en PDF
Rapid Voltage Change (RVC)
A rapid voltage change is a fast rise or fall of the RMS voltage. This can be caused by the switching on of a specific load or by a sudden change in source voltage. Sudden source voltage changes can occur in solar grids when the sun is obscured by clouds. Source voltage changes can also occur in wind farms when then wind speed decreases. Load switching can cause a rapid voltage change if the rating of the load is a significant fraction of the fault level of the supply voltage.
Publié : 29 avril 2020
Télécharger en PDF
Pumping Station Motor Analysis
This test was performed at a pumping station that was using multiple 600HP motors and a VFD drive. The reported problem was the plant was not receiving adequate power output from the motors during peak times. It was not possible to connect to the inputs of the motors themselves so an MPQ2000 was connected to the output of the VFD and the following measurements were recorded.
Publié : 29 avril 2020
Télécharger en PDF
MPQ1000 Common Connections
An application note locoking at the common connections of the MPQ1000.
Publié : 29 avril 2020
Télécharger en PDF
Merging MPQ Data Files
Adding, removing or changing a piece of equipment in a facility can have significant impacts on the power quality and energy requirements. Introduced power quality phenomenon can cause equipment to trip off line. This can represent significant losses in revenue. Added equipment can create high peak loads or increased reactive currents that can lead to penalties. In order to determine the impact of these changes a power quality and demand study should be performed prior to the change and after the change.
Publié : 29 avril 2020
Télécharger en PDF
  • <